Start here
A home survey looks at the visible condition of the electrics, gas, heating and water. It doesn’t test them. That’s not a gap in one firm’s service: testing an electrical installation or a gas appliance is a separate job for a qualified electrician or a Gas Safe registered engineer, with their own instruments and their own standards. What a good survey does is tell you when the services look old, altered or unsafe enough that you should get them tested before you exchange, and what to ask the seller for. This guide explains where the line falls.
- Survey report
- Condition ratings
- Slipped slates
Contents8 sections
What the surveyor looks at, and what they don’t
On a Level 2 or Level 3 survey, the services are inspected visually, as part of the whole building. The surveyor doesn’t take covers off, open up appliances or carry out tests. That boundary is set out in the terms you agree before the inspection, and the report says what couldn’t be checked.
Within that boundary, there is a lot a surveyor can see.
Electrics
- The consumer unit (the fuse box): its age and type, and whether it has modern protective devices or old rewireable fuses.
- Visible wiring: cable types that suggest an old installation, such as rubber or fabric-covered cables, or lead-sheathed wiring.
- Sockets, switches and fittings: damage, scorching, loose fittings, too few sockets, and signs of overloaded adaptors.
- Alterations and DIY: extra sockets on surface cable, lights added in bathrooms, wiring in lofts and outbuildings.
- Smoke alarms: whether there are any, and where.
Gas, boilers and heating
- The boiler: its approximate age, where it is, the condition of its casing and the visible pipework.
- The flue: where it discharges, how close it is to windows, doors and boundaries, and whether there is any visible staining or damage.
- Ventilation for appliances that need it, such as older gas fires.
- Signs of trouble: soot or staining around appliances, which is a warning sign that needs a Gas Safe engineer straight away.
- Carbon monoxide alarms: whether there are any near fuel-burning appliances.
- Radiators, pipework and controls: leaks, corrosion and obvious faults.
Other heating and energy systems
Oil tanks, solid-fuel stoves, heat pumps and solar panels are reported on as far as they can be seen: their condition, location and anything that needs specialist attention. If you’re buying a house with an oil tank or a heat pump, ask the seller for the installation and servicing records.
How the report flags the services
Because the services aren’t tested, they’re often the part of a survey report where you’ll see a recommendation for further investigation. That isn’t the surveyor hedging. It’s the honest answer when an installation has no recent test certificate, looks old, or has been altered, and the only way to know whether it is safe is a test by a specialist. Our guide to reading a survey report without panicking explains the condition ratings.
The electrical test: an EICR
An Electrical Installation Condition Report (EICR) is an inspection and test of the fixed wiring by a qualified electrician, against the national wiring standard, BS 7671. It covers the parts a survey can’t: insulation resistance, earthing, the protective devices and the circuits behind the walls.
An EICR records any problems with a code:
- C1: danger present, needing immediate action;
- C2: potentially dangerous, needing urgent action;
- C3: improvement recommended;
- FI: further investigation needed.
How often, and who must have one
- Owner-occupiers aren’t legally required to have an EICR. Electrical Safety First recommends one at least every ten years for owner-occupied homes, and it is well worth having when you buy a house whose electrical history is unknown.
- Private landlords in England must have the electrics inspected and tested at least every five years by a qualified person, under the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020, and give tenants a copy of the report. GOV.UK’s guidance now covers the social rented sector too.
What to ask the seller for
- the most recent EICR, if there is one;
- Electrical Installation Certificates or Minor Works Certificates for any recent work;
- a Building Regulations compliance certificate for notifiable work. In England, installing a new circuit, replacing the consumer unit, or adding to or altering circuits in a bathroom or shower room must be notified under Part P. A registered electrician in a competent person scheme self-certifies it; otherwise building control signs it off.
If an extension, loft conversion or kitchen has been added with no paperwork for the electrics, your conveyancer should ask why.
Gas: the Gas Safe check
By law, anyone working on gas appliances or pipework must be on the Gas Safe Register. You can check an engineer’s registration on the Gas Safe Register’s website, and every registered engineer carries an ID card.
How often, and who must have one
- Landlords must have every gas appliance and flue they provide checked by a Gas Safe registered engineer at least every 12 months, keep the record, and give tenants a copy, under the Gas Safety (Installation and Use) Regulations 1998. HSE’s guidance for landlords explains the duties.
- Owner-occupiers have no equivalent legal duty, but Gas Safe Register recommends having gas appliances safety-checked and serviced every year.
What to ask the seller for
- the boiler’s installation paperwork and any remaining manufacturer’s warranty;
- the service history;
- for a let property, the current gas safety record.
If there is no service history, budget for a Gas Safe engineer to check and service the boiler as soon as you move in, or ask for a check before exchange if the survey has raised concerns.
Carbon monoxide
Carbon monoxide has no smell, so an alarm is the only way to know it is there. Fit one in any room with a boiler, fire or stove. In rented homes in England, landlords have had to fit carbon monoxide alarms in any room used as living accommodation that contains a fixed combustion appliance (gas cookers excepted) since 1 October 2022, along with a smoke alarm on every storey.
Using the findings in your purchase
If the survey and the tests find that the house needs rewiring, a new consumer unit or a new boiler, that is real information for your negotiation, just like a roof repair. Get quotes from qualified trades rather than guessing, and see our guide to using your survey to negotiate.
Electrics and gas in older Yorkshire and North West houses
In the stone terraces and interwar semis that make up so much of our coverage area, the services have usually been changed piecemeal over decades: a newer consumer unit on old circuits, a combination boiler in a former coal-fired house, a flue run through a stone wall, a bathroom added in a former bedroom. None of that is necessarily a problem. It is the reason a survey so often recommends a test, and why the paperwork matters.
Book a survey that tells you what needs testing
Our Level 2 and Level 3 surveys report on the visible condition of the services and tell you plainly when a specialist test is the right next step. We don’t carry out electrical testing or gas work ourselves, so there is nothing for us to sell you afterwards. Send us the address for a fixed quote; we aim to reply within one working day.
Related service
The most popular survey for standard homes: condition ratings, maintenance advice and the matters to raise before exchange. Survey only, without valuation.
Level 2 from £335
About this serviceRequest a Level 2 survey quoteOr call 01484 218579
RICS-regulated firm no. 9317773
Free tools
Check your own property.
Sources and further reading
- Electrical safety standards in the private and social rented sectors: guidance — GOV.UK
- How long does an EICR last for? — Electrical Safety First
- Electrics: building regulations — Planning Portal
- Gas safety: landlords and letting agents — HSE
- The Gas Safety (Installation and Use) Regulations 1998 — legislation.gov.uk
- Gas Safe Register — the official register of gas engineers
- Smoke and carbon monoxide alarms: explanatory booklet for landlords — GOV.UK